Check and replacement should be made at a heated-up reducer of the bridge. |
Peredny Bridge
|
Location of jams jellied/control (1) and drain (2) openings of a case of the forward bridge |
Check
|
- Carefully wipe a surface of a case of the bridge round a stopper of a jellied/control (1) opening.
- Turn out a stopper, - oil level in a case should reach the bottom cut of an opening, in case of need make the corresponding adjustment (use a funnel). Track, that the stopper was tightened with demanded effort.
|
|
Replacement
|
- Prepare drain capacity of suitable volume.
- Having wiped a case surface, round both openings, turn out jellied (1) and drain (2) jams.
- Wait the terminations of an effluence of oil, then screw on the place and tighten with demanded effort a drain stopper (2), - in case of need previously replace a sealing washer.
- Through a funnel fill in in a reducer case necessary amount of fresh oil of a demanded grade, - level of oil should reach the bottom cut of a jellied/control opening.
- Screw and tighten with demanded effort a stopper (1).
|
|
Zadny Bridge
|
Location of jams jellied/control (1) and drain (2) openings of a case of the back bridge |
The order of performance of procedures is similar described above for the forward bridge.
|
For the purpose of ensuring normal access to a stopper of a jellied/control opening the car should be lowered on wheels. |
|
|