Mercedes-Benz G-class (W463) since 1999 of release
1. Introduction
2. Governing bodies and operation receptions
3. Current leaving and service
4. Engine
5. Systems of cooling, heating, ventilation and air conditioning
5.1. System of cooling of the engine
5.2. Systems of ventilation, heating and air conditioning
5.2.1. General information and security measures
5.2.2. Removal and control panel installation by functioning of systems of heating / ventilation / air conditioning
5.2.3. Removal and installation of the salonny filter
5.2.4. Removal and installation of the fan of the heater / conditioner of air and its module of management
5.2.5. Removal and installation of the heat exchanger of a heater
5.2.6. Removal and installation of the circulating pump of a heater
5.2.7. Removal and installation of back ventilating guards
5.2.8. Check of level of a coolant in a working path of To/in system
5.2.9. Removal and installation of sensors of To/in system
5.2.10. Removal and installation of auxiliary ventilyatorny assembly
5.2.11. Removal and installation of the electromotor of a drive of a ventilating zaslonka
5.2.12. Removal and installation of the step-by-step electromotor of a drive of a zaslonka of switching of modes of air circulation
5.2.13. Removal and installation of the electromotor of a drive of a mixing zaslonka
5.2.14. Removal and installation of the evaporator of To/in system and its casing
5.2.15. Removal and installation of the compressor of To/in system
5.2.16. Removal and installation of the condenser of To/in system
5.2.17. Removal and installation of the broad valve
5.2.18. Removal and receiver dehumidifier installation
6. A power supply system and production of the fulfilled gases
7. Systems of electric equipment of the engine
8. Automatic transmission
9. Transmission line
10. Brake and auxiliary systems
11. Suspension bracket and steering
12. Body
13. Onboard electric equipment
14. Schemes of electric connections


 









5-2-8-proverka-urovnya-khladagenta-v-rabochem-trakte-sistemy-k-v.html

5.2.8. Check of level of a coolant in a working path of To/in system

Observe all necessary precautionary measures connected with service of To/in systems (see. Section General information and security measures)!


Bolts of fastening of a forward decorative lattice

Location of an observation port of a receiver dehumidifier in an impellent compartment of models of release from 12.2000 g.

Location of an observation port of the receiver dehumidifier located ahead of a radiator

2 — the Socket of the sensor switch of low pressure

Location of an observation port of a receiver dehumidifier in an impellent compartment of models of release on 12.2000 g.

 PERFORMANCE ORDER

  1. If the receiver dehumidifier To/in is located ahead of a radiator, remove a forward decorative lattice (see. Head Body).
  2. Wipe glass of an observation port (shooter) on receiver dehumidifier assembly.
  3. Disunite the socket (2) of the low-pressure head sensor switch and перемкните plugs of the last.
  4. Start the engine on single turns.
  5. Turn on the fan of a heater and activate To/in system in a mode of the maximum hladoproizvoditelnost.
  6. Remove a crossing point from the socket of the sensor switch of pressure and, having glanced in an observation port of a receiver dehumidifier, make sure of lack of signs of a puzyreniye of a coolant (at primary start of svezhezapravlenny system formation of air bubbles should not cause concern, - wait about 10 minutes, - bubbles should disappear, the insignificant puzyreniye is also admissible at high [> 35°С] ambient temperatures)

At operation of the electromagnetic coupling of coupling of the compressor speed of a stream of liquid should increase.

  1. Attentively study an external condition of all components refrigerator To/in, by means of the special detector check them on existence of signs of development of leaks.
  2. Transfer the fan to a high-speed mode "1" and by means of a special measuring instrument measure temperature leaving via the central deflectors of the dashboard of air. 5 minutes of functioning of system later the temperature of air submitted to salon should be in range limits +2°С ÷ +12°С, and the To/in compressor should pass to a cyclic mode (in, otherwise it is necessary to check a condition of the sensor switch of temperature of the evaporator.
  3. Switch off the conditioner and muffle the engine, - more detailed checks of To/in system should be carried out in the conditions of a car-care center workshop.