6.2.6. Removal and installation of components of an inlet air pathAir purifier and air filter
|
Removal of a cover of the power unit with the built-in air purifier |
|
Details of installation of a filtering element of an air purifier |
|
- Having pulled up, uncover the power unit with the built-in air purifier (1).
- Take from under covers filtering element and establish instead of it replaceable.
- Establish into place a cover (1).
|
|
Air inlet assembly with the sensor of measurement of weight of air (MAF)
Details of installation of assembly of an air inlet with the MAF sensor
|
- Uncover the power unit with the built-in air purifier (1).
- Disconnect electroconducting (2) from the MAF sensor (B2/5).
- Disconnect the line of ventilation of a case (3).
- Liberate the line of ventilation of a case to the right of the MAF sensor (B2/5).
- By means of a screw-driver release a clamp of fastening of the MAF sensor (B2/5).
- Wring out down a clamp on the electronic activator of a butterfly valve and remove an air inlet (4) assembled with the MAF sensor (B2/5).
- Disconnect assembly of the sensor (B2/5) from an air inlet (4).
- Installation is made upside-down.
|
|
Inlet pipeline
Details of installation of the inlet pipeline
Scheme of connection of the inlet pipeline
|
- Remove air inlet assembly with the MAF sensor (see above).
- Remove the toplivoraspredelitelny highway with injectors (see. Section Removal and installation of the fuel distributive highway and injectors).
- Disconnect the corresponding electroconducting.
- Give a cap nut of fastening of the ventilating line (89/2) to the EGR (89) valve, - for prevention of a provorachivaniye of the union hold it the second key.
- Turn out fixing bolts (19/1) and remove the combined valve (6).
- Remove assembly of the inlet pipeline (19), - at once закупорьте inlet ports of the engine неворсящейся rags.
- Remove sealing laying (19/3), - laying is subject to replacement without fail.
- Installation is made upside-down. New laying at first is fixed by hairpins (track correctness of an arrangement of laying), which then are turned out directly ahead of pipeline installation.
|
|
Electronic activator of a drive of a butterfly valve
Details of installation of the electronic activator of a drive of a butterfly valve
|
- Uncover the power unit with the air purifier built in in it (see above).
- Remove air inlet assembly with the MAF sensor (see above).
- Disconnect from the inlet pipeline (19) the line of ventilation of a case (1/2).
- Disconnect electroconducting (shooter).
- Turn out fixing bolts (8/1) and remove the activator of a butterfly valve (M16/1), - prepare a replaceable sealing ring (8/2).
- Installation is made upside-down.
|
|
The Rezonatorny chamber with a catchment basin
Details of installation of the rezonatorny chamber of an inlet air path and catchment basin (all models) (1 of 2)
Details of installation of the rezonatorny chamber of an inlet air path and catchment basin (all models) (2 of 2)
|
- Open a cowl.
- Turn out three fixing bolts (1).
- Release a fixing collar (2) and remove a drainage hose (3), - for the purpose of ensuring access remove a loker (5) protection of a wheel arch (see. Head Body).
- Give a nut (7) and remove a collar (8).
- Remove assembly of the rezonatorny chamber with a catchment basin (9), - track, that the drainage hose was turned up.
- Check a condition of sealing laying (11), in case of need make its replacement.
- Installation is made upside-down. Before a vvorachivaniye (10) it is necessary to grease a bolt slightly, - track correctness of landing of a bolt in the directing.
|
|
|